ContiReflex® Enhanced Artificial Urinary Sphincter is used to treat urinary incontinence due to intrinsic sphincter deficiency in cases such as incontinence following prostate surgery.4
Unlike traditional devices, the ContiReflex® with its smart reflex balloon constantly senses intra-abdominal pressure changes and simultaneously adapts the pressure on the urethra, potentially helping patients stay dry more consistently.4
The Reflex Balloon, with its dual component design, allows adjustment of pressure on the urethra in response to the patient’s sudden intra-abdominal pressure changes, promising improved outcomes with the treatment of stress urinary incontinence. In effect, this means that cuff occlusion pressure is no longer limited by the PRB’s labeled pressure.
The ContiReflex’s unique two-component design allows the system to adjust cuff pressure in real time, based on intra-abdominal pressure changes. This means that it can potentially achieve satisfactory continence outcomes with a lower baseline pressure than traditional devices. The lower baseline pressure also helps to reduce stress on the urethra, which could lead to longer device lifespan and reduced risk of urethral complications.

balão com reflexo inteligente detecta IAP; altera e modifica a pressão oclusiva do manguito em tempo real. A pressão manguito oclusivo não é mais limitada pela capacidade de pressão rotulada do PRB.
- ContiReflex ® PRB Tamanhos
40 – 49 cm H20 50 – 59 cm H20 60 – 69 cm H20 70 – 79 cm H20 80 – 89 cm H20

ContiReflex® esfíncter urinário artificial aprimorado oferece uma ampla gama de tamanhos de manguitos oclusivos, proporcionando aos cirurgiões uma flexibilidade sem precedentes na adaptação do dispositivo à anatomia uretral exclusiva de cada paciente. A seleção diversificada de tamanhos de manguitos vai de 3,5 cm a 13,0 cm, com incrementos tão precisos quanto 0,25 cm em determinadas faixas, permitindo um ajuste excepcionalmente preciso. Esta extensa gama de opções permite que os cirurgiões obtenham um tratamento mais personalizado e potencialmente mais eficaz para pacientes com vários graus de incontinência urinária.
- ContiRegular ® manguito oclusivo
3,5 cm 5,5 cm 9,0 cm 3,75 cm 6,0 cm 9,5 cm 4,0 cm 6,5 cm 10,0 cm 4,25 cm 7,0 cm 11,0 cm 4,5 cm 7,5 cm 12,0 cm 4,75 cm 8,0 cm 13,0 cm

Ao contrário dos concorrentes, ContiReflex® é fabricado exclusivamente com um revestimento hidrofílico HydroShield™ em todas as superfícies externas, incluindo o balão regulador de pressão. O revestimento HydroShield™ permite diversas opções de imersão, permitindo uma abordagem personalizada para atender às necessidades específicas do cirurgião e do paciente.
Os tubos resistentes a torções são conectados fácil e manualmente, sem a necessidade de ferramentas de montagem adicionais.

A bomba de controle ContiReflex® se destaca por apresentar uma bomba extremamente suave, ativação pós-recuperação sem esforço e manipulação intuitiva da bomba para uma experiência aprimorada do paciente.

O ContiReflex® é totalmente compatível e pode ser implantado junto com qualquer um dos Infla10® sistema de prótese peniana inflável modelos5.

Os sistemas Conti™ esfíncter urinário artificial apresentam tubos resistentes a torções codificados por cores, que facilitam conexões intraoperatórias confiáveis entre os componentes do dispositivo para os cirurgiões. A utilização de KRTs azuis, em oposição aos KRTs transparentes em sistemas legados, melhora o controle visual para verificar a integridade da conexão.

passador de tubos, incluído no Conti™ kit de acessórios, fornece ao cirurgião implantador a facilidade de transferência perfeita do tubo entre duas incisões.

balão com reflexo inteligente detecta IAP; altera e modifica a pressão oclusiva do manguito em tempo real. A pressão manguito oclusivo não é mais limitada pela capacidade de pressão rotulada do PRB.
- ContiReflex ® PRB Tamanhos
40 – 49 cm H20 50 – 59 cm H20 60 – 69 cm H20 70 – 79 cm H20 80 – 89 cm H20
- ContiReflex ® PRB Tamanhos
40 – 49 cm H20 50 – 59 cm H20 60 – 69 cm H20 70 – 79 cm H20 80 – 89 cm H20

ContiReflex® esfíncter urinário artificial aprimorado oferece uma ampla gama de tamanhos de manguitos oclusivos, proporcionando aos cirurgiões uma flexibilidade sem precedentes na adaptação do dispositivo à anatomia uretral exclusiva de cada paciente. A seleção diversificada de tamanhos de manguitos vai de 3,5 cm a 13,0 cm, com incrementos tão precisos quanto 0,25 cm em determinadas faixas, permitindo um ajuste excepcionalmente preciso. Esta extensa gama de opções permite que os cirurgiões obtenham um tratamento mais personalizado e potencialmente mais eficaz para pacientes com vários graus de incontinência urinária.
- ContiRegular ® manguito oclusivo
3,5 cm 5,5 cm 9,0 cm 3,75 cm 6,0 cm 9,5 cm 4,0 cm 6,5 cm 10,0 cm 4,25 cm 7,0 cm 11,0 cm 4,5 cm 7,5 cm 12,0 cm 4,75 cm 8,0 cm 13,0 cm
- ContiRegular ® manguito oclusivo
3,5 cm 5,5 cm 9,0 cm 3,75 cm 6,0 cm 9,5 cm 4,0 cm 6,5 cm 10,0 cm 4,25 cm 7,0 cm 11,0 cm 4,5 cm 7,5 cm 12,0 cm 4,75 cm 8,0 cm 13,0 cm

Ao contrário dos concorrentes, ContiReflex® é fabricado exclusivamente com um revestimento hidrofílico HydroShield™ em todas as superfícies externas, incluindo o balão regulador de pressão. O revestimento HydroShield™ permite diversas opções de imersão, permitindo uma abordagem personalizada para atender às necessidades específicas do cirurgião e do paciente.
Os tubos resistentes a torções são conectados fácil e manualmente, sem a necessidade de ferramentas de montagem adicionais.

A bomba de controle ContiReflex® se destaca por apresentar uma bomba extremamente suave, ativação pós-recuperação sem esforço e manipulação intuitiva da bomba para uma experiência aprimorada do paciente.

O ContiReflex® é totalmente compatível e pode ser implantado junto com qualquer um dos Infla10® sistema de prótese peniana inflável modelos5.

Os sistemas Conti™ esfíncter urinário artificial apresentam tubos resistentes a torções codificados por cores, que facilitam conexões intraoperatórias confiáveis entre os componentes do dispositivo para os cirurgiões. A utilização de KRTs azuis, em oposição aos KRTs transparentes em sistemas legados, melhora o controle visual para verificar a integridade da conexão.

passador de tubos, incluído no Conti™ kit de acessórios, fornece ao cirurgião implantador a facilidade de transferência perfeita do tubo entre duas incisões.


balão com reflexo inteligente

manguito oclusivo

EasyClick™ Connector

Tubo resistente a torções

Botão de desativação

bomba de controle
O sistema ContiReflex® foi projetado para ajudar os pacientes a recuperar o controle da função urinária. Consiste em três componentes principais: um balão com reflexo inteligente colocado no abdômen, um manguito oclusivo posicionado ao redor da uretra e uma bomba de controle localizada no escroto. Quando a bomba de controle é ativada, o manguito aperta ao redor da uretra para evitar vazamento de urina. Para urinar, o paciente aperta a bomba de controle, que afrouxa temporariamente o manguito, permitindo a passagem da urina. Este sistema é uma solução eficaz para pacientes que sofrem de incontinência urinária, proporcionando um método discreto e confiável para controlar o controle da bexiga.
|
ContiReflex® |
|
Encontre informações de segurança importantes e indicações para o ContiReflex® esfíncter urinário artificial aprimorado usado no tratamento da incontinência urinária. |
Conti™ Artificial Urinary Sphincter
Product Code | ContiRegular® manguito oclusivo |
|---|---|
| CTR-OC35 | 3.5 cm |
| CTR-OC375 | 3.75 cm |
| CTR-OC40 | 4.0 cm |
| CTR-OC425 | 4.25 cm |
| CTR-OC45 | 4.5 cm |
| CTR-OC475 | 4.75 cm |
| CTR-OC50 | 5.0 cm |
| CTR-OC55 | 5.5 cm |
| CTR-OC60 | 6.0 cm |
| CTR-OC65 | 6.5 cm |
| CTR-OC70 | 7.0 cm |
| CTR-OC75 | 7.5 cm |
| CTR-OC80 | 8.0 cm |
| CTR-OC85 | 8.5 cm |
| CTR-OC90 | 9.0 cm |
| CTR-OC95 | 9.5 cm |
| CTR-OC100 | 10.0 cm |
| CTR-OC110 | 11.0 cm |
| CTR-OC120 | 12.0 cm |
| CTR-OC130 | 13.0 cm |
Product Code | Accessory Kit |
|---|---|
| CT-AK | Conti™ Accessory Kit |
How does the balão com reflexo inteligente in ContiReflex® enhance the treatment of stress urinary incontinence?
The unique balão com reflexo inteligente in ContiReflex® is designed to sense changes in intraabdominal pressure and adapt the pressure on the urethra accordingly. This dynamic adjustment potentially offers improved patient outcomes with stress urinary incontinence, particularly during activities that increase abdominal pressure, like coughing or exercising. It ensures that cuff occlusion pressure is responsive to bodily movements, providing reliable continence control.
Can the ContiReflex® Artificial Urinary Sphincter be used in combination with treatments for erectile dysfunction?
Sim, ContiReflex® is compatible with the Infla10® Inflatable Penile Prosthesis, allowing for concurrent management of stress urinary incontinence and erectile dysfunction. This compatibility is particularly beneficial for patients who have undergone prostate surgery and are experiencing both conditions. The integration of these devices provides a comprehensive approach to post-prostatectomy rehabilitation.
What can I expect in terms of recovery after getting the ContiReflex® Artificial Urinary Sphincter? When can I return to normal activities?
The recovery period following the implantation of ContiReflex® typically lasts up to 6 weeks, but this can vary depending on individual circumstances. During the first 4-6 weeks post-surgery, we generally advise patients to avoid demanding activities. Your physician will activate the device at a follow-up appointment within this period. You’ll receive specific guidance for your recovery, but most patients gradually resume their normal activities, ensuring a comfortable and successful recovery process.
Is the ContiReflex® device noticeable? Will others be able to tell that I have it implanted?
No, the ContiReflex® is designed to be completely discreet. All of its components are internally implanted and fully concealed within your body. There are no visible signs of the device externally, so your privacy and comfort are maintained. Rest assured that the device is designed to be discreet and unnoticeable to others, allowing you to confidently engage in your daily activities.
I’m concerned about the ease of using the ContiReflex® device. How simple is it to operate the control pump?
The ContiReflex® is designed with ease of use in mind, particularly when it comes to the control pump. This pump is engineered to be very user-friendly, allowing easy manipulation. You’ll be able to manage the device with minimal effort, providing control over urinary continence without significant physical strain or complexity. Your physician will guide you on how to use the pump effectively, ensuring you feel confident in managing the device independently.
Are there any unique features of the ContiReflex® that make it stand out compared to other artificial urinary sphincters?
Sim, the ContiReflex® has several unique features. Its innovative Reflex Balloon adapts to changes in intra-abdominal pressure, providing real-time adjustment for potentially better continence control. Additionally, the device offers a range of cuff sizes for a precise fit and a hydrophilic coating compatible with various antibiotics, enhancing surgical flexibility and patient-specific care. These features collectively contribute to the device’s effectiveness and patient comfort, making it a distinguished choice in the treatment of stress urinary incontinence.
As someone who’s active and enjoys sports, how will the ContiReflex® affect my lifestyle? Can I continue with activities like gym workouts or running?
The ContiReflex® is designed to adapt to changes in intraabdominal pressure, making it suitable for active lifestyles. After the initial recovery period, nearly all patients can return to their regular physical activities, including gym workouts and running. The device’s ability to respond to pressure changes means it provides protection during various movements. However, we recommend discussing your specific activity level with your physician to get personalized advice on resuming such activities post-implantation.
Will I need to make any long-term adjustments or lifestyle changes after the ContiReflex® implantation?
While ContiReflex® is designed to enhance your quality of life and provide better control over urinary incontinence, some lifestyle adjustments may be beneficial post-implantation. These might include managing fluid intake, and avoiding excessive demanding activities, and regular follow-up appointments to ensure the device is functioning optimally. Your physician will provide detailed guidance based on your individual situation to ensure the best outcomes with your ContiReflex®.
I’ve had urinary incontinence for a while. How effective is the ContiReflex® in managing long-term incontinence issues?
Artificial Urinary Sphincter systems are proven to be highly effective for long-term management of stress urinary incontinence, especially in cases arising from intrinsic sphincter deficiency, such as after prostate surgery. ContiReflex®’s innovative design, including the Reflex Balloon, provides dynamic pressure adjustment, enhancing continence control.
Are there any specific considerations or care routines I should follow to maintain the ContiReflex® device’s effectiveness over time?
To maintain the effectiveness of your ContiReflex®, it’s important to adhere to the care routines advised by your physician. This includes regular check-ups to monitor the device’s function, proper handling of the control pump, and being mindful of activities that could impact the device. Additionally, maintaining a healthy lifestyle, managing fluid intake, and avoiding activities that exert excessive pressure on the abdominal area can contribute to the long-term success of the device.
FAQ’s Disclaimer
The content is not intended to be a substitute for, nor does it replace professional medical advice, diagnosis, or treatment. If you have any concerns or questions about your health, you should always consult with a physician or other health-care professional.
-
A lei federal (EUA) restringe a venda deste dispositivo a médicos ou mediante prescrição médica.
-
Não disponível para venda nos Estados Unidos.