{"id":32627,"date":"2026-09-03T18:49:00","date_gmt":"2026-09-03T22:49:00","guid":{"rendered":"https:\/\/www.rigicon.com\/?post_type=glossary-term&p=32627"},"modified":"2026-09-04T06:14:00","modified_gmt":"2026-09-04T10:14:00","slug":"angiografia-por-ressonancia-magnetica-arm","status":"publish","type":"glossary-term","link":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/","title":{"rendered":"Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":0,"template":"","glossary-category":[141],"glossary-product":[104,105],"class_list":["post-32627","glossary-term","type-glossary-term","status-publish","hentry","glossary-category-erectile-dysfunction-treatments","glossary-product-infla10-pulse-ipp-series","glossary-product-rigi10-malleable-penile-prosthesis"],"acf":{"gt-definition":"<p>A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) \u00e9 uma t\u00e9cnica especializada e n\u00e3o invasiva de resson\u00e2ncia magn\u00e9tica especificamente projetada para visualizar vasos sangu\u00edneos e avaliar a fun\u00e7\u00e3o vascular na avalia\u00e7\u00e3o da disfun\u00e7\u00e3o er\u00e9til<sup>1<\/sup>. Essa modalidade avan\u00e7ada de imagem utiliza o encurtamento transit\u00f3rio do tempo de relaxamento ponderado em T1 do sangue ap\u00f3s a inje\u00e7\u00e3o intravenosa de quelatos de gadol\u00ednio para criar imagens detalhadas da vasculatura peniana<sup>2<\/sup>. Ao contr\u00e1rio da angiografia tradicional, que requer a inser\u00e7\u00e3o de cateter no corpo, a ARM oferece uma alternativa mais segura e menos invasiva para uma avalia\u00e7\u00e3o vascular abrangente<sup>3<\/sup>.<\/p>\n<p>No contexto da avalia\u00e7\u00e3o da disfun\u00e7\u00e3o er\u00e9til, a ARM emprega sequ\u00eancias de imagens contrastadas com resolu\u00e7\u00e3o temporal (time-resolved) para fornecer resolu\u00e7\u00e3o temporal e espacial, permitindo a visualiza\u00e7\u00e3o de anormalidades arteriais e venosas que possam contribuir para a disfun\u00e7\u00e3o er\u00e9til<sup>1<\/sup>. A t\u00e9cnica normalmente envolve uma sequ\u00eancia tridimensional de ARM ponderada em T1 com eco de gradiente spoiled (spoiled gradient echo) realizada ao longo de 3 minutos com uma taxa de quadros de 4,6 segundos ap\u00f3s a inje\u00e7\u00e3o intracavernosa de um agente eretog\u00eanico<sup>1<\/sup>. Sequ\u00eancias adicionais ponderadas em T1 e T2 s\u00e3o realizadas para colocaliza\u00e7\u00e3o anat\u00f4mica e caracteriza\u00e7\u00e3o tecidual, proporcionando uma avalia\u00e7\u00e3o abrangente da anatomia e fun\u00e7\u00e3o vascular peniana<sup>1<\/sup>.<\/p>\n<p>O principal mecanismo da ARM na avalia\u00e7\u00e3o da disfun\u00e7\u00e3o er\u00e9til envolve a detec\u00e7\u00e3o de anomalias vasculares, incluindo o enchimento precoce de veias de drenagem, malforma\u00e7\u00f5es arteriovenosas, f\u00edstulas e a avalia\u00e7\u00e3o dos padr\u00f5es de realce cavernoso<sup>1<\/sup>. Esta t\u00e9cnica de imagem surgiu como uma modalidade preferida em rela\u00e7\u00e3o \u00e0 angiotomografia computadorizada devido \u00e0 sua resolu\u00e7\u00e3o de imagem superior e capacidades de avalia\u00e7\u00e3o angiogr\u00e1fica mais precisas na investiga\u00e7\u00e3o da disfun\u00e7\u00e3o er\u00e9til arteriog\u00eanica<sup>4<\/sup>. A ARM pode fornecer uma avalia\u00e7\u00e3o angioanat\u00f4mica precisa das art\u00e9rias segmentares destinadas ao p\u00eanis, auxiliando os cirurgi\u00f5es na preserva\u00e7\u00e3o desses vasos e reduzindo o risco de disfun\u00e7\u00e3o er\u00e9til p\u00f3s-operat\u00f3ria<sup>4<\/sup>.<\/p>","gt-synonyms":"Angioresson\u00e2ncia Magn\u00e9tica, Angiografia por RM, Angio-RM Din\u00e2mica, ARM com Resolu\u00e7\u00e3o Temporal, ARM Contrastada, ARM com Gadol\u00ednio, ARM Peniana, RM Vascular","gt-citation":"[1] Roudenko A, Wilcox Vanden Berg RN, Song C, Prince MR, Paduch DA, Margolis D. Utility of dynamic MRA in the evaluation of male erectile dysfunction. Abdom Radiol (NY). 2020;45(2):378-387. DOI: https:\/\/doi.org\/10.1007\/s00261-019-02339-y\n\n[2] Ma M, Yu B, Qin F, Yuan J. Current approaches to the diagnosis of vascular erectile dysfunction. Transl Androl Urol. 2020;9(2):709-721. DOI: https:\/\/doi.org\/10.21037\/tau.2020.03.10\n\n[3] Johns Hopkins Medicine. Magnetic Resonance Angiography (MRA). Available at: https:\/\/www.hopkinsmedicine.org\/health\/treatment-tests-and-therapies\/magnetic-resonance-angiography-mra\n\n[4] Chung E. Contemporary and Novel Imaging Studies for the Evaluation of Erectile Dysfunction. Med Sci (Basel). 2019;7(8):87. DOI: https:\/\/doi.org\/10.3390\/medsci7080087\n\n[5] Wilcox Vanden Berg R, Roudenko A, Song C, Prince MR, Paduch DA, Margolis D. Dynamic Magnetic Resonance Angiography in Men with Idiopathic Erectile Dysfunction. J Urol. 2018;199(4S):e1017. DOI: https:\/\/doi.org\/10.1016\/j.juro.2018.02.3017\n\n[6] Stehling MK, Rosen MP, Weintraub J, Kim D, Raptopoulos V. Gadolinium-enhanced magnetic resonance angiography of penile arteries: anatomy and initial clinical experience. Eur Radiol. 1997;7(7):1016-1021. DOI: https:\/\/doi.org\/10.1007\/BF02594588","gt-clinical-context":"<p>A Angiografia por Resson\u00e2ncia Magn\u00e9tica \u00e9 indicada clinicamente para a avalia\u00e7\u00e3o de homens jovens com suspeita de anomalias vasculares aberrantes que contribuem para a disfun\u00e7\u00e3o er\u00e9til, particularmente aqueles que demonstram sinais de shunt vascular precoce no exame de ultrassonografia com Doppler peniano (PDUS)<sup>1,5<\/sup>. A t\u00e9cnica atua como uma ferramenta diagn\u00f3stica valiosa para pacientes com suspeita cl\u00ednica de anomalias vasculares em que informa\u00e7\u00f5es anat\u00f4micas detalhadas s\u00e3o necess\u00e1rias antes da interven\u00e7\u00e3o cir\u00fargica<sup>1<\/sup>.<\/p>\n<p>Os crit\u00e9rios de sele\u00e7\u00e3o de pacientes para ARM na avalia\u00e7\u00e3o da disfun\u00e7\u00e3o er\u00e9til incluem homens que apresentam suspeita de disfun\u00e7\u00e3o er\u00e9til arteriog\u00eanica, particularmente pacientes mais jovens em que anomalias vasculares possam ser a causa subjacente<sup>1,5<\/sup>. O procedimento \u00e9 especialmente ben\u00e9fico para pacientes considerados para cirurgia de revasculariza\u00e7\u00e3o peniana, pois fornece um mapeamento vascular detalhado que pode orientar o planejamento cir\u00fargico<sup>1<\/sup>. A avalia\u00e7\u00e3o por ARM serve como uma ferramenta \u00fatil para identificar shunts arteriovenosos e determinar a etiologia espec\u00edfica da disfun\u00e7\u00e3o er\u00e9til<sup>5<\/sup>.<\/p>\n<p>O procedimento cl\u00ednico envolve a inje\u00e7\u00e3o intracavernosa de agentes vasoativos seguida de imagens de ARM com contraste<sup>1<\/sup>. Os pacientes s\u00e3o submetidos a imagens contrastadas com resolu\u00e7\u00e3o temporal utilizando 0,1 mMol\/kg de gadobutrol a 1 ml\/s seguido de flush de solu\u00e7\u00e3o salina<sup>1<\/sup>. O exame avalia drenagem venosa precoce anormal, realce cavernoso diminuto ou tardio, tumesc\u00eancia incompleta e doen\u00e7a combinada de influxo arterial\/efluxo venoso<sup>1<\/sup>.<\/p>\n<p>Os desfechos cl\u00ednicos demonstram que a ARM apresenta uma concord\u00e2ncia de 85,2% com a ultrassonografia com Doppler peniano na determina\u00e7\u00e3o da presen\u00e7a ou aus\u00eancia de shunts ou malforma\u00e7\u00f5es arteriovenosas<sup>1<\/sup>. Em um estudo de 29 exames de ARM em 26 pacientes com idade m\u00e9dia de 39 anos, a t\u00e9cnica demonstrou com sucesso drenagem venosa precoce anormal em 22 casos, realce cavernoso diminuto\/tardio em 3 casos, tumesc\u00eancia incompleta em 2 casos e doen\u00e7a combinada de influxo arterial\/efluxo venoso em 1 caso<sup>1<\/sup>.<\/p>\n<p>O tempo de recupera\u00e7\u00e3o esperado ap\u00f3s o exame de ARM \u00e9 m\u00ednimo, pois o procedimento n\u00e3o \u00e9 invasivo e \u00e9 tipicamente realizado em regime ambulatorial<sup>3<\/sup>. As taxas de sucesso quanto \u00e0 acur\u00e1cia diagn\u00f3stica s\u00e3o elevadas, com a t\u00e9cnica fornecendo informa\u00e7\u00f5es anat\u00f4micas detalhadas que permitem aos m\u00e9dicos realizar um planejamento pr\u00e9-cir\u00fargico abrangente e aconselhamento ao paciente<sup>1<\/sup>.<\/p>","gt-related-evidence":null,"gt-featured":true,"gt-ai-referenced":true,"gt-view-count":2},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.4 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til<\/title>\n<meta name=\"description\" content=\"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til\" \/>\n<meta property=\"og:description\" content=\"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/\" \/>\n<meta property=\"og:site_name\" content=\"Rigicon\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/rigiconurology\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-04T10:14:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1440\" \/>\n\t<meta property=\"og:image:height\" content=\"718\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til\" \/>\n<meta name=\"twitter:description\" content=\"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.\" \/>\n<meta name=\"twitter:site\" content=\"@rigiconurology\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/glossary-term\\\/angiografia-por-ressonancia-magnetica-arm\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/glossary-term\\\/angiografia-por-ressonancia-magnetica-arm\\\/\",\"name\":\"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/#website\"},\"datePublished\":\"2026-09-03T22:49:00+00:00\",\"dateModified\":\"2026-09-04T10:14:00+00:00\",\"description\":\"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/glossary-term\\\/angiografia-por-ressonancia-magnetica-arm\\\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/glossary-term\\\/angiografia-por-ressonancia-magnetica-arm\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/glossary-term\\\/angiografia-por-ressonancia-magnetica-arm\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Glossary Terms\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/urology-glossary\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/#website\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/\",\"name\":\"Rigicon\",\"description\":\"Innovative Urological Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/#organization\"},\"alternateName\":\"Innovative Urological Solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/#organization\",\"name\":\"Rigicon, Inc.\",\"alternateName\":\"Innovative Urological Solutions\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"contentUrl\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"width\":512,\"height\":512,\"caption\":\"Rigicon, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/pt-br\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/x.com\\\/rigiconurology\",\"https:\\\/\\\/www.instagram.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@Rigicon\\\/podcasts\",\"https:\\\/\\\/www.youtube.com\\\/Rigicon\",\"https:\\\/\\\/www.threads.net\\\/@rigiconurology\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/rigicon\\\/\"],\"description\":\"Rigicon is a global provider of innovative, diverse, and complete portfolio of prosthetic urology options.\",\"email\":\"operations@rigicon.com\",\"telephone\":\"+1 (888) 202-9790\",\"legalName\":\"Rigicon, Inc.\",\"vatID\":\"81-3545645\",\"taxID\":\"81-3545645\",\"duns\":\"045247683\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til","description":"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/","og_locale":"pt_BR","og_type":"article","og_title":"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til","og_description":"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.","og_url":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/","og_site_name":"Rigicon","article_publisher":"https:\/\/www.facebook.com\/rigiconurology\/","article_modified_time":"2026-09-04T10:14:00+00:00","og_image":[{"width":1440,"height":718,"url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_title":"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til","twitter_description":"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.","twitter_site":"@rigiconurology","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/","url":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/","name":"Angiografia por Resson\u00e2ncia Magn\u00e9tica na Disfun\u00e7\u00e3o Er\u00e9til","isPartOf":{"@id":"https:\/\/www.rigicon.com\/pt-br\/#website"},"datePublished":"2026-09-03T22:49:00+00:00","dateModified":"2026-09-04T10:14:00+00:00","description":"A Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM) avalia vasos sangu\u00edneos penianos para investigar causas vasculares de disfun\u00e7\u00e3o er\u00e9til com alta precis\u00e3o.","breadcrumb":{"@id":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rigicon.com\/pt-br\/glossary-term\/angiografia-por-ressonancia-magnetica-arm\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/www.rigicon.com\/pt-br\/"},{"@type":"ListItem","position":2,"name":"Glossary Terms","item":"https:\/\/www.rigicon.com\/pt-br\/urology-glossary\/"},{"@type":"ListItem","position":3,"name":"Angiografia por Resson\u00e2ncia Magn\u00e9tica (ARM)"}]},{"@type":"WebSite","@id":"https:\/\/www.rigicon.com\/pt-br\/#website","url":"https:\/\/www.rigicon.com\/pt-br\/","name":"Rigicon","description":"Innovative Urological Solutions","publisher":{"@id":"https:\/\/www.rigicon.com\/pt-br\/#organization"},"alternateName":"Innovative Urological Solutions","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rigicon.com\/pt-br\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/www.rigicon.com\/pt-br\/#organization","name":"Rigicon, Inc.","alternateName":"Innovative Urological Solutions","url":"https:\/\/www.rigicon.com\/pt-br\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/www.rigicon.com\/pt-br\/#\/schema\/logo\/image\/","url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","contentUrl":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","width":512,"height":512,"caption":"Rigicon, Inc."},"image":{"@id":"https:\/\/www.rigicon.com\/pt-br\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/rigiconurology\/","https:\/\/x.com\/rigiconurology","https:\/\/www.instagram.com\/rigiconurology\/","https:\/\/www.youtube.com\/@Rigicon\/podcasts","https:\/\/www.youtube.com\/Rigicon","https:\/\/www.threads.net\/@rigiconurology","https:\/\/www.linkedin.com\/company\/rigicon\/"],"description":"Rigicon is a global provider of innovative, diverse, and complete portfolio of prosthetic urology options.","email":"operations@rigicon.com","telephone":"+1 (888) 202-9790","legalName":"Rigicon, Inc.","vatID":"81-3545645","taxID":"81-3545645","duns":"045247683"}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.rigicon.com\/pt-br\/wp-json\/wp\/v2\/glossary-term\/32627","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rigicon.com\/pt-br\/wp-json\/wp\/v2\/glossary-term"}],"about":[{"href":"https:\/\/www.rigicon.com\/pt-br\/wp-json\/wp\/v2\/types\/glossary-term"}],"wp:attachment":[{"href":"https:\/\/www.rigicon.com\/pt-br\/wp-json\/wp\/v2\/media?parent=32627"}],"wp:term":[{"taxonomy":"glossary-category","embeddable":true,"href":"https:\/\/www.rigicon.com\/pt-br\/wp-json\/wp\/v2\/glossary-category?post=32627"},{"taxonomy":"glossary-product","embeddable":true,"href":"https:\/\/www.rigicon.com\/pt-br\/wp-json\/wp\/v2\/glossary-product?post=32627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}