{"id":32868,"date":"2026-09-01T18:49:00","date_gmt":"2026-09-01T22:49:00","guid":{"rendered":"https:\/\/www.rigicon.com\/?post_type=glossary-term&p=32868"},"modified":"2026-09-02T06:14:00","modified_gmt":"2026-09-02T10:14:00","slug":"evaluacion-de-la-electrobioimpedancia-nocturna","status":"publish","type":"glossary-term","link":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/","title":{"rendered":"Evaluaci\u00f3n de la electrobioimpedancia nocturna"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":0,"template":"","glossary-category":[109],"glossary-product":[105],"class_list":["post-32868","glossary-term","type-glossary-term","status-publish","hentry","glossary-category-diagnostic-phenomena","glossary-product-rigi10-malleable-penile-prosthesis"],"acf":{"gt-definition":"<p>La evaluaci\u00f3n volum\u00e9trica por electrobioimpedancia nocturna (NEVA) es un procedimiento diagn\u00f3stico que mide los cambios en el volumen peneano durante las erecciones nocturnas para la evaluaci\u00f3n de la disfunci\u00f3n er\u00e9ctil (ED)<sup>1<\/sup>. La t\u00e9cnica se basa en el principio de administrar una corriente alterna constante y no detectable al tejido peneano y medir los cambios resultantes en la impedancia, los cuales se correlacionan con las variaciones del volumen sangu\u00edneo durante las erecciones<sup>2<\/sup>. A partir de estas mediciones, se pueden determinar la longitud, el \u00e1rea de secci\u00f3n transversal y el volumen peneano, lo que permite calcular el n\u00famero y la duraci\u00f3n de los episodios er\u00e9ctiles, el cambio de volumen y el porcentaje de aumento de volumen respecto al valor basal<sup>3<\/sup>.<\/p>\n<p>El dispositivo NEVA consta de tres conjuntos de electrodos y un peque\u00f1o registrador. Un conjunto de electrodos se aplica en la base del pene, otro se coloca a nivel subcoronal (cerca del glande) y un electrodo de referencia se sit\u00faa en la cadera<sup>4<\/sup>. El registrador se lleva c\u00f3modamente en la parte superior del muslo, lo que permite la monitorizaci\u00f3n domiciliaria durante varias noches consecutivas<sup>1<\/sup>.<\/p>\n<p>La NEVA aporta datos objetivos sobre la funci\u00f3n er\u00e9ctil nocturna, lo que ayuda a los cl\u00ednicos a diferenciar entre las causas psic\u00f3genas y org\u00e1nicas de la disfunci\u00f3n er\u00e9ctil<sup>3<\/sup>. Los estudios han demostrado que los pacientes con ED presentan menos episodios er\u00e9ctiles nocturnos que resultan en un menor incremento del volumen sangu\u00edneo peneano respecto al valor basal en comparaci\u00f3n con individuos sin ED<sup>1<\/sup>. Adem\u00e1s, la NEVA puede distinguir potencialmente entre diferentes tipos de impotencia org\u00e1nica, como la insuficiencia arterial y la disfunci\u00f3n venooclusiva<sup>2<\/sup>, algo que no es posible con la monitorizaci\u00f3n tradicional de la tumescencia peneana nocturna (NPT)<sup>4<\/sup>.<\/p>","gt-synonyms":"NEVA, evaluaci\u00f3n volum\u00e9trica por electrobioimpedancia nocturna, evaluaci\u00f3n peneana por electrobioimpedancia, electrobioimpedancia peneana nocturna","gt-citation":"[1] Knoll LD, Abrams JH. Nocturnal electrobioimpedance volumetric assessment of patients with erectile dysfunction. Urology. 1999 Jun;53(6):1200-4. DOI: 10.1016\/s0090-4295(99)00017-5\n\n[2] Knoll LD, Abrams JH. Application of nocturnal electrobioimpedance volumetric assessment: a feasibility study in men without erectile dysfunction. J Urol. 1999;161(4):1136-1140. DOI: 10.1016\/S0022-5347(01)61612-4\n\n[3] Salama N. Nocturnal electrobioimpedance volumetric assessment in diabetic men with erectile dysfunction before and after tadalafil intake. Int J Impot Res. 2004;16:441-447. DOI: 10.1038\/sj.ijir.3901203\n\n[4] Michielsen DPJ, Amy JJ. Nocturnal Electrobioimpedance Volumetric Assessment (NEVA\u00ae): an alternative for determining the quality of nocturnal erections. Arch Med Sci. 2005;1(2):110-114.","gt-clinical-context":"<p>La evaluaci\u00f3n volum\u00e9trica por electrobioimpedancia nocturna se utiliza principalmente en la evaluaci\u00f3n diagn\u00f3stica de la disfunci\u00f3n er\u00e9ctil (ED)<sup>1<\/sup>. El procedimiento ayuda a los cl\u00ednicos a diferenciar entre causas psic\u00f3genas y org\u00e1nicas de la ED al proporcionar mediciones objetivas de las erecciones peneanas nocturnas<sup>3<\/sup>. Esta distinci\u00f3n es crucial para determinar las estrategias terap\u00e9uticas adecuadas, ya que la ED psic\u00f3gena puede responder mejor a intervenciones psicol\u00f3gicas, mientras que la ED org\u00e1nica suele requerir tratamiento m\u00e9dico o quir\u00fargico<sup>2<\/sup>.<\/p>\n<p>La selecci\u00f3n de pacientes para la NEVA suele incluir a varones con sospecha de ED cuando la etiolog\u00eda no est\u00e1 clara o cuando se necesitan datos objetivos a efectos del seguro m\u00e9dico<sup>4<\/sup>. El procedimiento es especialmente valioso en los casos en que la distinci\u00f3n entre causas psic\u00f3genas y org\u00e1nicas no resulta evidente a partir de la anamnesis o la exploraci\u00f3n f\u00edsica del paciente<sup>1<\/sup>.<\/p>\n<p>El procedimiento NEVA es no invasivo y puede realizarse en el entorno domiciliario del paciente, lo que lo convierte en una alternativa pr\u00e1ctica a los estudios del sue\u00f1o en laboratorio<sup>1<\/sup>. Por lo general, los pacientes llevan puesto el dispositivo durante 2 o 3 noches consecutivas para obtener datos fiables<sup>3<\/sup>. Los datos recogidos incluyen el n\u00famero y la duraci\u00f3n de los episodios er\u00e9ctiles, as\u00ed como el porcentaje de cambio de volumen respecto al valor basal<sup>1<\/sup>.<\/p>\n<p>La investigaci\u00f3n ha demostrado que la NEVA puede distinguir potencialmente entre diferentes tipos de impotencia org\u00e1nica, como la insuficiencia arterial y la disfunci\u00f3n venooclusiva<sup>2<\/sup>, lo cual no es posible con la monitorizaci\u00f3n tradicional de la tumescencia peneana nocturna (NPT)<sup>4<\/sup>. Esta capacidad permite un seguimiento diagn\u00f3stico y una planificaci\u00f3n terap\u00e9utica m\u00e1s orientados<sup>2<\/sup>.<\/p>\n<p>Los estudios han demostrado una buena correlaci\u00f3n entre las mediciones de la NEVA y otros m\u00e9todos diagn\u00f3sticos como la ecograf\u00eda Doppler d\u00faplex<sup>1<\/sup>. En estudios comparativos, los pacientes con ED presentaron menos episodios er\u00e9ctiles nocturnos que resultaron en un menor incremento del volumen sangu\u00edneo peneano respecto al valor basal en comparaci\u00f3n con individuos sin ED<sup>1<\/sup>.<\/p>\n<p>Los resultados esperados de la prueba NEVA incluyen la documentaci\u00f3n objetiva de la funci\u00f3n er\u00e9ctil, la diferenciaci\u00f3n entre causas psic\u00f3genas y org\u00e1nicas de la ED y posibles datos sobre el tipo espec\u00edfico de impotencia org\u00e1nica cuando est\u00e1 presente<sup>2<\/sup>. Esta informaci\u00f3n orienta las evaluaciones diagn\u00f3sticas posteriores y las decisiones terap\u00e9uticas, mejorando potencialmente los resultados de los pacientes<sup>3<\/sup>.<\/p>","gt-related-evidence":null,"gt-featured":false,"gt-ai-referenced":true,"gt-view-count":2},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.4 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Evaluaci\u00f3n de electrobioimpedancia nocturna<\/title>\n<meta name=\"description\" content=\"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Evaluaci\u00f3n de electrobioimpedancia nocturna\" \/>\n<meta property=\"og:description\" content=\"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/\" \/>\n<meta property=\"og:site_name\" content=\"Rigicon\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/rigiconurology\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-02T10:14:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1440\" \/>\n\t<meta property=\"og:image:height\" content=\"718\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Evaluaci\u00f3n de electrobioimpedancia nocturna\" \/>\n<meta name=\"twitter:description\" content=\"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.\" \/>\n<meta name=\"twitter:site\" content=\"@rigiconurology\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/evaluacion-de-la-electrobioimpedancia-nocturna\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/evaluacion-de-la-electrobioimpedancia-nocturna\\\/\",\"name\":\"Evaluaci\u00f3n de electrobioimpedancia nocturna\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#website\"},\"datePublished\":\"2026-09-01T22:49:00+00:00\",\"dateModified\":\"2026-09-02T10:14:00+00:00\",\"description\":\"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/evaluacion-de-la-electrobioimpedancia-nocturna\\\/#breadcrumb\"},\"inLanguage\":\"es-ES\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/evaluacion-de-la-electrobioimpedancia-nocturna\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/evaluacion-de-la-electrobioimpedancia-nocturna\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Glossary Terms\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/urology-glossary\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Evaluaci\u00f3n de la electrobioimpedancia nocturna\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/\",\"name\":\"Rigicon\",\"description\":\"Innovative Urological Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#organization\"},\"alternateName\":\"Innovative Urological Solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-ES\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#organization\",\"name\":\"Rigicon, Inc.\",\"alternateName\":\"Innovative Urological Solutions\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-ES\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"contentUrl\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"width\":512,\"height\":512,\"caption\":\"Rigicon, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/x.com\\\/rigiconurology\",\"https:\\\/\\\/www.instagram.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@Rigicon\\\/podcasts\",\"https:\\\/\\\/www.youtube.com\\\/Rigicon\",\"https:\\\/\\\/www.threads.net\\\/@rigiconurology\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/rigicon\\\/\"],\"description\":\"Rigicon is a global provider of innovative, diverse, and complete portfolio of prosthetic urology options.\",\"email\":\"operations@rigicon.com\",\"telephone\":\"+1 (888) 202-9790\",\"legalName\":\"Rigicon, Inc.\",\"vatID\":\"81-3545645\",\"taxID\":\"81-3545645\",\"duns\":\"045247683\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Evaluaci\u00f3n de electrobioimpedancia nocturna","description":"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/","og_locale":"es_ES","og_type":"article","og_title":"Evaluaci\u00f3n de electrobioimpedancia nocturna","og_description":"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.","og_url":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/","og_site_name":"Rigicon","article_publisher":"https:\/\/www.facebook.com\/rigiconurology\/","article_modified_time":"2026-09-02T10:14:00+00:00","og_image":[{"width":1440,"height":718,"url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_title":"Evaluaci\u00f3n de electrobioimpedancia nocturna","twitter_description":"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.","twitter_site":"@rigiconurology","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/","url":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/","name":"Evaluaci\u00f3n de electrobioimpedancia nocturna","isPartOf":{"@id":"https:\/\/www.rigicon.com\/es\/#website"},"datePublished":"2026-09-01T22:49:00+00:00","dateModified":"2026-09-02T10:14:00+00:00","description":"La evaluaci\u00f3n de la electrobioimpedancia nocturna mide cambios de volumen peneano para diagnosticar la disfunci\u00f3n er\u00e9ctil y guiar su tratamiento.","breadcrumb":{"@id":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/#breadcrumb"},"inLanguage":"es-ES","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rigicon.com\/es\/glossary-term\/evaluacion-de-la-electrobioimpedancia-nocturna\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.rigicon.com\/es\/"},{"@type":"ListItem","position":2,"name":"Glossary Terms","item":"https:\/\/www.rigicon.com\/es\/urology-glossary\/"},{"@type":"ListItem","position":3,"name":"Evaluaci\u00f3n de la electrobioimpedancia nocturna"}]},{"@type":"WebSite","@id":"https:\/\/www.rigicon.com\/es\/#website","url":"https:\/\/www.rigicon.com\/es\/","name":"Rigicon","description":"Innovative Urological Solutions","publisher":{"@id":"https:\/\/www.rigicon.com\/es\/#organization"},"alternateName":"Innovative Urological Solutions","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rigicon.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-ES"},{"@type":"Organization","@id":"https:\/\/www.rigicon.com\/es\/#organization","name":"Rigicon, Inc.","alternateName":"Innovative Urological Solutions","url":"https:\/\/www.rigicon.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es-ES","@id":"https:\/\/www.rigicon.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","contentUrl":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","width":512,"height":512,"caption":"Rigicon, Inc."},"image":{"@id":"https:\/\/www.rigicon.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/rigiconurology\/","https:\/\/x.com\/rigiconurology","https:\/\/www.instagram.com\/rigiconurology\/","https:\/\/www.youtube.com\/@Rigicon\/podcasts","https:\/\/www.youtube.com\/Rigicon","https:\/\/www.threads.net\/@rigiconurology","https:\/\/www.linkedin.com\/company\/rigicon\/"],"description":"Rigicon is a global provider of innovative, diverse, and complete portfolio of prosthetic urology options.","email":"operations@rigicon.com","telephone":"+1 (888) 202-9790","legalName":"Rigicon, Inc.","vatID":"81-3545645","taxID":"81-3545645","duns":"045247683"}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-term\/32868","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-term"}],"about":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/types\/glossary-term"}],"wp:attachment":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/media?parent=32868"}],"wp:term":[{"taxonomy":"glossary-category","embeddable":true,"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-category?post=32868"},{"taxonomy":"glossary-product","embeddable":true,"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-product?post=32868"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}