{"id":32611,"date":"2026-09-03T18:49:00","date_gmt":"2026-09-03T22:49:00","guid":{"rendered":"https:\/\/www.rigicon.com\/?post_type=glossary-term&p=32611"},"modified":"2026-10-07T01:11:19","modified_gmt":"2026-10-07T05:11:19","slug":"angiografia-por-resonancia-magnetica-arm","status":"publish","type":"glossary-term","link":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/","title":{"rendered":"Angiograf\u00eda por resonancia magn\u00e9tica (ARM)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":0,"template":"","glossary-category":[141],"glossary-product":[104,105],"class_list":["post-32611","glossary-term","type-glossary-term","status-publish","hentry","glossary-category-erectile-dysfunction-treatments","glossary-product-infla10-pulse-ipp-series","glossary-product-rigi10-malleable-penile-prosthesis"],"acf":{"gt-definition":"<p>La angiograf\u00eda por resonancia magn\u00e9tica (ARM) es una t\u00e9cnica especializada y m\u00ednimamente invasiva de resonancia magn\u00e9tica dise\u00f1ada espec\u00edficamente para visualizar los vasos sangu\u00edneos y evaluar la funci\u00f3n vascular en el estudio de la disfunci\u00f3n er\u00e9ctil<sup>1<\/sup>. Esta modalidad de imagen avanzada aprovecha el acortamiento transitorio del tiempo de relajaci\u00f3n T1 de la sangre tras la inyecci\u00f3n intravenosa de quelatos de gadolinio para obtener im\u00e1genes detalladas de la vascularizaci\u00f3n del pene<sup>2<\/sup>. A diferencia de la angiograf\u00eda tradicional, que requiere la inserci\u00f3n de un cat\u00e9ter en el cuerpo, la ARM ofrece una alternativa m\u00e1s segura y menos invasiva para una evaluaci\u00f3n vascular completa<sup>3<\/sup>.<\/p>\n\n<p>En el contexto de la evaluaci\u00f3n de la disfunci\u00f3n er\u00e9ctil, la ARM emplea secuencias de imagen con contraste y resoluci\u00f3n temporal que proporcionan resoluci\u00f3n tanto temporal como espacial, lo que permite visualizar anomal\u00edas arteriales y venosas que pueden contribuir a la disfunci\u00f3n er\u00e9ctil<sup>1<\/sup>. La t\u00e9cnica suele consistir en una secuencia de ARM 3D potenciada en T1 de eco de gradiente con destrucci\u00f3n de la magnetizaci\u00f3n transversal (spoiled), realizada durante 3 minutos con una frecuencia de adquisici\u00f3n de un fotograma cada 4,6 segundos, tras la inyecci\u00f3n intracavernosa de un agente erect\u00f3geno<sup>1<\/sup>. Se realizan secuencias adicionales potenciadas en T1 y en T2 para la colocalizaci\u00f3n anat\u00f3mica y la caracterizaci\u00f3n tisular, lo que proporciona una evaluaci\u00f3n completa de la anatom\u00eda y la funci\u00f3n vasculares del pene<sup>1<\/sup>.<\/p>\n\n<p>El principal mecanismo de la ARM en la evaluaci\u00f3n de la disfunci\u00f3n er\u00e9ctil consiste en la detecci\u00f3n de anomal\u00edas vasculares, como el llenado precoz de las venas de drenaje, las malformaciones arteriovenosas y las f\u00edstulas, as\u00ed como en la evaluaci\u00f3n de los patrones de realce cavernoso<sup>1<\/sup>. Esta t\u00e9cnica de imagen se ha consolidado como una modalidad preferida frente a la angiograf\u00eda por tomograf\u00eda computarizada debido a su mayor resoluci\u00f3n de imagen y a su evaluaci\u00f3n angiogr\u00e1fica m\u00e1s precisa en el estudio de la disfunci\u00f3n er\u00e9ctil arteri\u00f3gena<sup>4<\/sup>. La ARM puede proporcionar una evaluaci\u00f3n angioanat\u00f3mica precisa de las arterias segmentarias destinadas al pene, lo que ayuda a los cirujanos a preservar estos vasos y a reducir el riesgo de disfunci\u00f3n er\u00e9ctil posoperatoria<sup>4<\/sup>.<\/p>","gt-synonyms":"Angiograf\u00eda por resonancia magn\u00e9tica, Angiorresonancia magn\u00e9tica, Angiograf\u00eda por RM, ARM din\u00e1mica, ARM con resoluci\u00f3n temporal, ARM con contraste, ARM con gadolinio, ARM peneana, RM vascular","gt-citation":"[1] Roudenko A, Wilcox Vanden Berg RN, Song C, Prince MR, Paduch DA, Margolis D. Utility of dynamic MRA in the evaluation of male erectile dysfunction. Abdom Radiol (NY). 2020;45(2):378-387. DOI: https:\/\/doi.org\/10.1007\/s00261-019-02339-y\n\n[2] Ma M, Yu B, Qin F, Yuan J. Current approaches to the diagnosis of vascular erectile dysfunction. Transl Androl Urol. 2020;9(2):709-721. DOI: https:\/\/doi.org\/10.21037\/tau.2020.03.10\n\n[3] Johns Hopkins Medicine. Magnetic Resonance Angiography (MRA). Available at: https:\/\/www.hopkinsmedicine.org\/health\/treatment-tests-and-therapies\/magnetic-resonance-angiography-mra\n\n[4] Chung E. Contemporary and Novel Imaging Studies for the Evaluation of Erectile Dysfunction. Med Sci (Basel). 2019;7(8):87. DOI: https:\/\/doi.org\/10.3390\/medsci7080087\n\n[5] Wilcox Vanden Berg R, Roudenko A, Song C, Prince MR, Paduch DA, Margolis D. Dynamic Magnetic Resonance Angiography in Men with Idiopathic Erectile Dysfunction. J Urol. 2018;199(4S):e1017. DOI: https:\/\/doi.org\/10.1016\/j.juro.2018.02.3017\n\n[6] Stehling MK, Rosen MP, Weintraub J, Kim D, Raptopoulos V. Gadolinium-enhanced magnetic resonance angiography of penile arteries: anatomy and initial clinical experience. Eur Radiol. 1997;7(7):1016-1021. DOI: https:\/\/doi.org\/10.1007\/BF02594588","gt-clinical-context":"<p>La angiograf\u00eda por resonancia magn\u00e9tica est\u00e1 indicada cl\u00ednicamente para la evaluaci\u00f3n de hombres j\u00f3venes con sospecha de anomal\u00edas vasculares aberrantes que contribuyen a la disfunci\u00f3n er\u00e9ctil, en particular aquellos que muestran signos de cortocircuito vascular precoz en la ecograf\u00eda Doppler peneana (PDUS)<sup>1,5<\/sup>. La t\u00e9cnica constituye una valiosa herramienta diagn\u00f3stica para pacientes con sospecha cl\u00ednica de anomal\u00edas vasculares en los que se requiere informaci\u00f3n anat\u00f3mica detallada antes de la intervenci\u00f3n quir\u00fargica<sup>1<\/sup>.<\/p>\n\n<p>Los criterios de selecci\u00f3n de pacientes para la ARM en la evaluaci\u00f3n de la disfunci\u00f3n er\u00e9ctil incluyen a los hombres que presentan sospecha de disfunci\u00f3n er\u00e9ctil arteri\u00f3gena, en particular los pacientes m\u00e1s j\u00f3venes, en quienes las anomal\u00edas vasculares pueden ser la causa subyacente<sup>1,5<\/sup>. El procedimiento es especialmente \u00fatil para los pacientes candidatos a cirug\u00eda de revascularizaci\u00f3n peneana, ya que proporciona un mapa vascular detallado que puede orientar la planificaci\u00f3n quir\u00fargica<sup>1<\/sup>. La evaluaci\u00f3n mediante ARM es una herramienta \u00fatil para identificar cortocircuitos arteriovenosos y determinar la etiolog\u00eda espec\u00edfica de la disfunci\u00f3n er\u00e9ctil<sup>5<\/sup>.<\/p>\n\n<p>El procedimiento cl\u00ednico consiste en la inyecci\u00f3n intracavernosa de agentes vasoactivos seguida de una ARM con contraste<sup>1<\/sup>. Los pacientes se someten a im\u00e1genes con contraste y resoluci\u00f3n temporal utilizando 0,1 mMol\/kg de gadobutrol a 1 ml\/s, seguido de un lavado con soluci\u00f3n salina<sup>1<\/sup>. El estudio eval\u00faa la presencia de drenaje venoso precoz an\u00f3malo, realce cavernoso disminuido o tard\u00edo, tumescencia incompleta y enfermedad combinada de entrada arterial\/salida venosa<sup>1<\/sup>.<\/p>\n\n<p>Los resultados cl\u00ednicos demuestran que la ARM tiene una concordancia del 85,2% con la ecograf\u00eda Doppler peneana para determinar la presencia o ausencia de cortocircuitos o malformaciones arteriovenosos<sup>1<\/sup>. En un estudio de 29 exploraciones de ARM realizadas en 26 pacientes con una edad media de 39 a\u00f1os, la t\u00e9cnica demostr\u00f3 drenaje venoso precoz an\u00f3malo en 22 casos, realce cavernoso disminuido\/tard\u00edo en 3 casos, tumescencia incompleta en 2 casos y enfermedad combinada de entrada arterial\/salida venosa en 1 caso<sup>1<\/sup>.<\/p>\n\n<p>El tiempo de recuperaci\u00f3n esperado tras la ARM es m\u00ednimo, ya que el procedimiento es m\u00ednimamente invasivo y suele realizarse de forma ambulatoria<sup>3<\/sup>. Las tasas de \u00e9xito en cuanto a precisi\u00f3n diagn\u00f3stica son elevadas, y la t\u00e9cnica aporta informaci\u00f3n anat\u00f3mica detallada que permite a los cl\u00ednicos llevar a cabo una planificaci\u00f3n prequir\u00fargica y un asesoramiento al paciente completos<sup>1<\/sup>.<\/p>","gt-related-evidence":null,"gt-featured":true,"gt-ai-referenced":true,"gt-view-count":28},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.7 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda<\/title>\n<meta name=\"description\" content=\"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda\" \/>\n<meta property=\"og:description\" content=\"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/\" \/>\n<meta property=\"og:site_name\" content=\"Rigicon\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/rigiconurology\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-07T05:11:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1440\" \/>\n\t<meta property=\"og:image:height\" content=\"718\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda\" \/>\n<meta name=\"twitter:description\" content=\"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.\" \/>\n<meta name=\"twitter:site\" content=\"@rigiconurology\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/angiografia-por-resonancia-magnetica-arm\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/angiografia-por-resonancia-magnetica-arm\\\/\",\"name\":\"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#website\"},\"datePublished\":\"2026-09-03T22:49:00+00:00\",\"dateModified\":\"2026-10-07T05:11:19+00:00\",\"description\":\"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/angiografia-por-resonancia-magnetica-arm\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/angiografia-por-resonancia-magnetica-arm\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/glossary-term\\\/angiografia-por-resonancia-magnetica-arm\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Glossary Terms\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/urology-glossary\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Angiograf\u00eda por resonancia magn\u00e9tica (ARM)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/\",\"name\":\"Rigicon\",\"description\":\"Innovative Urological Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#organization\"},\"alternateName\":\"Innovative Urological Solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#organization\",\"name\":\"Rigicon, Inc.\",\"alternateName\":\"Innovative Urological Solutions\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"contentUrl\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"width\":512,\"height\":512,\"caption\":\"Rigicon, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/x.com\\\/rigiconurology\",\"https:\\\/\\\/www.instagram.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@Rigicon\\\/podcasts\",\"https:\\\/\\\/www.youtube.com\\\/Rigicon\",\"https:\\\/\\\/www.threads.com\\\/@rigiconurology\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/rigicon\\\/\",\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q141595822\"],\"description\":\"Rigicon es un fabricante especializado con sede en EE. UU. de dispositivos de urolog\u00eda prot\u00e9sica: pr\u00f3tesis de pene, esf\u00ednteres urinarios artificiales y pr\u00f3tesis testiculares, comercializados en m\u00e1s de 75 pa\u00edses.\",\"email\":\"operations@rigicon.com\",\"telephone\":\"+1 (888) 202-9790\",\"legalName\":\"Rigicon, Inc.\",\"vatID\":\"81-3545645\",\"taxID\":\"81-3545645\",\"duns\":\"045247683\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda","description":"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/","og_locale":"es_ES","og_type":"article","og_title":"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda","og_description":"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.","og_url":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/","og_site_name":"Rigicon","article_publisher":"https:\/\/www.facebook.com\/rigiconurology\/","article_modified_time":"2026-10-07T05:11:19+00:00","og_image":[{"width":1440,"height":718,"url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_title":"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda","twitter_description":"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.","twitter_site":"@rigiconurology","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/","url":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/","name":"Angiograf\u00eda por resonancia magn\u00e9tica (ARM) en urolog\u00eda","isPartOf":{"@id":"https:\/\/www.rigicon.com\/es\/#website"},"datePublished":"2026-09-03T22:49:00+00:00","dateModified":"2026-10-07T05:11:19+00:00","description":"La angiograf\u00eda por resonancia magn\u00e9tica (ARM) eval\u00faa los vasos peneanos para el diagn\u00f3stico preciso de la disfunci\u00f3n er\u00e9ctil de origen vascular.","breadcrumb":{"@id":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rigicon.com\/es\/glossary-term\/angiografia-por-resonancia-magnetica-arm\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.rigicon.com\/es\/"},{"@type":"ListItem","position":2,"name":"Glossary Terms","item":"https:\/\/www.rigicon.com\/es\/urology-glossary\/"},{"@type":"ListItem","position":3,"name":"Angiograf\u00eda por resonancia magn\u00e9tica (ARM)"}]},{"@type":"WebSite","@id":"https:\/\/www.rigicon.com\/es\/#website","url":"https:\/\/www.rigicon.com\/es\/","name":"Rigicon","description":"Innovative Urological Solutions","publisher":{"@id":"https:\/\/www.rigicon.com\/es\/#organization"},"alternateName":"Innovative Urological Solutions","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rigicon.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.rigicon.com\/es\/#organization","name":"Rigicon, Inc.","alternateName":"Innovative Urological Solutions","url":"https:\/\/www.rigicon.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.rigicon.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","contentUrl":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","width":512,"height":512,"caption":"Rigicon, Inc."},"image":{"@id":"https:\/\/www.rigicon.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/rigiconurology\/","https:\/\/x.com\/rigiconurology","https:\/\/www.instagram.com\/rigiconurology\/","https:\/\/www.youtube.com\/@Rigicon\/podcasts","https:\/\/www.youtube.com\/Rigicon","https:\/\/www.threads.com\/@rigiconurology","https:\/\/www.linkedin.com\/company\/rigicon\/","https:\/\/www.wikidata.org\/wiki\/Q141595822"],"description":"Rigicon es un fabricante especializado con sede en EE. UU. de dispositivos de urolog\u00eda prot\u00e9sica: pr\u00f3tesis de pene, esf\u00ednteres urinarios artificiales y pr\u00f3tesis testiculares, comercializados en m\u00e1s de 75 pa\u00edses.","email":"operations@rigicon.com","telephone":"+1 (888) 202-9790","legalName":"Rigicon, Inc.","vatID":"81-3545645","taxID":"81-3545645","duns":"045247683"}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-term\/32611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-term"}],"about":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/types\/glossary-term"}],"wp:attachment":[{"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/media?parent=32611"}],"wp:term":[{"taxonomy":"glossary-category","embeddable":true,"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-category?post=32611"},{"taxonomy":"glossary-product","embeddable":true,"href":"https:\/\/www.rigicon.com\/es\/wp-json\/wp\/v2\/glossary-product?post=32611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}