{"id":11913,"date":"2025-08-06T10:17:03","date_gmt":"2025-08-06T14:17:03","guid":{"rendered":"https:\/\/www.rigicon.com\/glossary-term\/corporal-crossover\/"},"modified":"2026-10-06T18:04:57","modified_gmt":"2026-10-06T22:04:57","slug":"korporaler-crossover","status":"publish","type":"glossary-term","link":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/","title":{"rendered":"Korporaler Crossover"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":0,"template":"","glossary-category":[141],"glossary-product":[104,105],"class_list":["post-11913","glossary-term","type-glossary-term","status-publish","hentry","glossary-category-erectile-dysfunction-treatments","glossary-product-infla10-pulse-ipp-series","glossary-product-rigi10-malleable-penile-prosthesis"],"acf":{"gt-definition":"<p>Der korporale Crossover ist eine intraoperative oder postoperative Komplikation der Penisprothesenimplantation, bei der ein Prothesenzylinder versehentlich durch eine Perforation oder Fensterung im Septum der Schwellk\u00f6rper von einem Corpus cavernosum in das andere gelangt<sup>1<\/sup>. Diese Komplikation tritt auf, wenn der Dilatator, das Furlow-Instrument oder der Prothesenzylinder bei der Dilatation der Schwellk\u00f6rper oder der Platzierung des Zylinders die Septumwand durchdringt und so eine abnorme Verbindung zwischen den beiden Schwellk\u00f6rperkammern entsteht<sup>2<\/sup>. Die gefensterte Struktur der mittleren und distalen Septumwand der Schwellk\u00f6rper macht sie bei der Instrumentierung besonders anf\u00e4llig f\u00fcr Verletzungen<sup>3<\/sup>. Dieser \u00dcbertritt kann sowohl proximal als auch distal in den Corpora cavernosa auftreten, wobei distale Crossover h\u00e4ufiger berichtet werden<sup>4<\/sup>. Die Folge ist eine asymmetrische Zylinderlage, die zu Penisdeformit\u00e4t, Verk\u00fcrzung und Funktionsst\u00f6rungen f\u00fchren kann, wenn sie nicht rasch erkannt und korrigiert wird<sup>5<\/sup>.<\/p>","gt-synonyms":"Zylinder-Crossover, Prothesen-Crossover, Septumperforation mit Crossover, interkorporale Zylindermigration, Korporalkammer-Crossover","gt-citation":"[1] Wang C, Barreto Guimaraes PV, Raheem O, Kocjancic E. Reconstruction of Complex Midline Septal Corporal Defect in a Distal Crossover Penile Implant Cylinder: A Step-by-step Demonstration of Surgical Technique. J Sex Med. 2024;21(Supplement_1):qdae001.186. DOI: https:\/\/doi.org\/10.1093\/jsxmed\/qdae001.186\n\n[2] Antonini G, Busetto GM, Del Giudice F, et al. Distal Corporal Anchoring Stitch: A Technique to Address Distal Corporal Crossovers and Impending Lateral Extrusions of a Penile Prosthesis. J Sex Med. 2017;14(6):767-773. DOI: https:\/\/doi.org\/10.1016\/j.jsxm.2017.04.669\n\n[3] Raheem OA, Kalidoss S, Pomar HA, Suarez-Sarmiento A Jr, Perito P. Double distal corporal anchoring stitch for lateral penile implant cylinder extrusion. J Sex Med. 2024;21(10):967-970. DOI: https:\/\/doi.org\/10.1093\/jsxmed\/qdae100\n\n[4] Pearlman AM, Terlecki RP. Proximal Corporal Perforation During Penile Prosthesis Surgery: Prevention, Recognition, and Review of Historical and Novel Management Strategies. J Sex Med. 2018;15(7):1055-1060. DOI: https:\/\/doi.org\/10.1016\/j.jsxm.2018.04.635\n\n[5] Chung E, Solomon M, DeYoung L, Brock GB. Clinical outcomes and patient satisfaction rates among elderly male aged \u226575 years with inflatable penile prosthesis implant for medically refractory erectile dysfunction. World J Urol. 2014;32(1):173-177. DOI: https:\/\/doi.org\/10.1007\/s00345-013-1102-7. PMID: 23708698","gt-clinical-context":"<p>Der korporale Crossover tritt klinisch bei der Implantation hydraulischer (aufblasbarer) Penisprothesen (IPP) auf, insbesondere bei Patienten mit bestimmten Risikofaktoren<sup>1<\/sup>. Die Komplikation wird bei infrapubischem oder subkoronalem Zugang h\u00e4ufiger beobachtet als beim penoskrotalen Zugang<sup>2<\/sup>. Zu den Risikofaktoren geh\u00f6ren Schwellk\u00f6rperfibrose, Peyronie-Krankheit, eine vorangegangene Bestrahlung des Beckens und operationstechnische Fehler<sup>3<\/sup>.<\/p>\n\n<p>Intraoperativ kann ein Crossover vermutet werden, wenn beim \u201eGoal-Post-Test\u201c asymmetrische L\u00e4ngenmessungen der Schwellk\u00f6rper vorliegen, das Einf\u00fchren des zweiten Zylinders schwierig ist oder w\u00e4hrend der Dilatation ein h\u00f6rbares \u201eKlirren\u201c der Metallinstrumente auftritt<sup>4<\/sup>. Klinische Zeichen sind eine von der Mittellinie abweichende Lage des Harnr\u00f6hrenkatheters bei aktivierter Prothese und ein atypisches Erscheinungsbild des Penis beim Aufpumpen<sup>5<\/sup>.<\/p>\n\n<p>Postoperativ k\u00f6nnen Patienten eine schmerzhafte Links- oder Rechtskr\u00fcmmung des Penis bei der Erektion, eine unvollst\u00e4ndige Entleerung der Prothese, eine geneigte Glans oder einen asymmetrisch erigierten Penis bei aufgepumpten Zylindern aufweisen<sup>1<\/sup>. Die Diagnose wird in der Regel mittels Magnetresonanztomographie (MRT) best\u00e4tigt, die die abnorme Zylinderlage deutlich darstellen kann<sup>5<\/sup>.<\/p>\n\n<p>Die Behandlung erfordert eine chirurgische Korrektur durch Korporotomie, Septumrekonstruktion (h\u00e4ufig unter Verwendung biologischer Grafts wie Tutoplast) und Umlenkung des verlagerten Zylinders in den richtigen Schwellk\u00f6rperraum<sup>1<\/sup>. Zu den fortgeschrittenen Techniken geh\u00f6rt die distale korporale Ankernaht-Methode, die hervorragende Ergebnisse bei minimalen Komplikationen gezeigt hat<sup>2<\/sup>. Die Erfolgsraten der chirurgischen Korrektur sind hoch, wenn sie von erfahrenen prothetischen Urologen durchgef\u00fchrt wird, wobei die meisten Patienten eine wiederhergestellte Erektionsf\u00e4higkeit und eine einwandfreie Funktion (Aufpumpen und Entleeren) der Prothese erreichen<sup>4<\/sup>.<\/p>","gt-related-evidence":null,"gt-featured":true,"gt-ai-referenced":false,"gt-view-count":74},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.7 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Korporaler Crossover<\/title>\n<meta name=\"description\" content=\"Corporal Crossover tritt auf, wenn Prothesenzylinder w\u00e4hrend einer Implantation durch Septumdefekte zwischen Peniskammern wechseln.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Korporaler Crossover - Prosthetic Urology Glossary\" \/>\n<meta property=\"og:description\" content=\"Explore Rigicon\u2019s evidence-based glossary covering penile implants, AUS, ED treatments, and surgical terms in prosthetic urology.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/\" \/>\n<meta property=\"og:site_name\" content=\"Rigicon\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/rigiconurology\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-06T22:04:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1440\" \/>\n\t<meta property=\"og:image:height\" content=\"718\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@rigiconurology\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/glossary-term\\\/korporaler-crossover\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/glossary-term\\\/korporaler-crossover\\\/\",\"name\":\"Korporaler Crossover\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/#website\"},\"datePublished\":\"2025-08-06T14:17:03+00:00\",\"dateModified\":\"2026-10-06T22:04:57+00:00\",\"description\":\"Corporal Crossover tritt auf, wenn Prothesenzylinder w\u00e4hrend einer Implantation durch Septumdefekte zwischen Peniskammern wechseln.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/glossary-term\\\/korporaler-crossover\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.rigicon.com\\\/de\\\/glossary-term\\\/korporaler-crossover\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/glossary-term\\\/korporaler-crossover\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Glossary Terms\",\"item\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/urology-glossary\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Korporaler Crossover\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/\",\"name\":\"Rigicon\",\"description\":\"Innovative Urological Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/#organization\"},\"alternateName\":\"Innovative Urological Solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/#organization\",\"name\":\"Rigicon, Inc.\",\"alternateName\":\"Innovative Urological Solutions\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"contentUrl\":\"https:\\\/\\\/www.rigicon.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/cropped-Logo-Square-Kopya.jpg\",\"width\":512,\"height\":512,\"caption\":\"Rigicon, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rigicon.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/x.com\\\/rigiconurology\",\"https:\\\/\\\/www.instagram.com\\\/rigiconurology\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@Rigicon\\\/podcasts\",\"https:\\\/\\\/www.youtube.com\\\/Rigicon\",\"https:\\\/\\\/www.threads.com\\\/@rigiconurology\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/rigicon\\\/\",\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q141595822\"],\"description\":\"Rigicon ist ein in den USA ans\u00e4ssiger Spezialhersteller von Produkten f\u00fcr die prothetische Urologie: Penisprothesen, k\u00fcnstliche Harnschlie\u00dfmuskeln und Hodenprothesen, vertrieben in mehr als 75 L\u00e4ndern.\",\"email\":\"operations@rigicon.com\",\"telephone\":\"+1 (888) 202-9790\",\"legalName\":\"Rigicon, Inc.\",\"vatID\":\"81-3545645\",\"taxID\":\"81-3545645\",\"duns\":\"045247683\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Korporaler Crossover","description":"Corporal Crossover tritt auf, wenn Prothesenzylinder w\u00e4hrend einer Implantation durch Septumdefekte zwischen Peniskammern wechseln.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/","og_locale":"de_DE","og_type":"article","og_title":"Korporaler Crossover - Prosthetic Urology Glossary","og_description":"Explore Rigicon\u2019s evidence-based glossary covering penile implants, AUS, ED treatments, and surgical terms in prosthetic urology.","og_url":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/","og_site_name":"Rigicon","article_publisher":"https:\/\/www.facebook.com\/rigiconurology\/","article_modified_time":"2026-10-06T22:04:57+00:00","og_image":[{"width":1440,"height":718,"url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2025\/05\/header-d.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@rigiconurology","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/","url":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/","name":"Korporaler Crossover","isPartOf":{"@id":"https:\/\/www.rigicon.com\/de\/#website"},"datePublished":"2025-08-06T14:17:03+00:00","dateModified":"2026-10-06T22:04:57+00:00","description":"Corporal Crossover tritt auf, wenn Prothesenzylinder w\u00e4hrend einer Implantation durch Septumdefekte zwischen Peniskammern wechseln.","breadcrumb":{"@id":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rigicon.com\/de\/glossary-term\/korporaler-crossover\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.rigicon.com\/de\/"},{"@type":"ListItem","position":2,"name":"Glossary Terms","item":"https:\/\/www.rigicon.com\/de\/urology-glossary\/"},{"@type":"ListItem","position":3,"name":"Korporaler Crossover"}]},{"@type":"WebSite","@id":"https:\/\/www.rigicon.com\/de\/#website","url":"https:\/\/www.rigicon.com\/de\/","name":"Rigicon","description":"Innovative Urological Solutions","publisher":{"@id":"https:\/\/www.rigicon.com\/de\/#organization"},"alternateName":"Innovative Urological Solutions","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rigicon.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.rigicon.com\/de\/#organization","name":"Rigicon, Inc.","alternateName":"Innovative Urological Solutions","url":"https:\/\/www.rigicon.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.rigicon.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","contentUrl":"https:\/\/www.rigicon.com\/wp-content\/uploads\/2024\/07\/cropped-Logo-Square-Kopya.jpg","width":512,"height":512,"caption":"Rigicon, Inc."},"image":{"@id":"https:\/\/www.rigicon.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/rigiconurology\/","https:\/\/x.com\/rigiconurology","https:\/\/www.instagram.com\/rigiconurology\/","https:\/\/www.youtube.com\/@Rigicon\/podcasts","https:\/\/www.youtube.com\/Rigicon","https:\/\/www.threads.com\/@rigiconurology","https:\/\/www.linkedin.com\/company\/rigicon\/","https:\/\/www.wikidata.org\/wiki\/Q141595822"],"description":"Rigicon ist ein in den USA ans\u00e4ssiger Spezialhersteller von Produkten f\u00fcr die prothetische Urologie: Penisprothesen, k\u00fcnstliche Harnschlie\u00dfmuskeln und Hodenprothesen, vertrieben in mehr als 75 L\u00e4ndern.","email":"operations@rigicon.com","telephone":"+1 (888) 202-9790","legalName":"Rigicon, Inc.","vatID":"81-3545645","taxID":"81-3545645","duns":"045247683"}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.rigicon.com\/de\/wp-json\/wp\/v2\/glossary-term\/11913","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rigicon.com\/de\/wp-json\/wp\/v2\/glossary-term"}],"about":[{"href":"https:\/\/www.rigicon.com\/de\/wp-json\/wp\/v2\/types\/glossary-term"}],"wp:attachment":[{"href":"https:\/\/www.rigicon.com\/de\/wp-json\/wp\/v2\/media?parent=11913"}],"wp:term":[{"taxonomy":"glossary-category","embeddable":true,"href":"https:\/\/www.rigicon.com\/de\/wp-json\/wp\/v2\/glossary-category?post=11913"},{"taxonomy":"glossary-product","embeddable":true,"href":"https:\/\/www.rigicon.com\/de\/wp-json\/wp\/v2\/glossary-product?post=11913"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}